Request a Quote
Leave Your Message

PM2.5 Online Enriched Rodent Whole-body Exposure System

The PM2.5 Online Enriched Rodent Whole-body Exposure System consists of slit impact PM2.5 online enrichment system and dynamic whole-body exposure system for rodents. It can efficiently concentrate fine particles by 6-10 times, simulate higher than PM2.5 exposure environment, and build a research platform for scientists to study effects between fine particle haze and human health in polluted environment.

    Features

    1. Cutting size and collection efficiency of PM2.5 sampler can meet requirements of HJ93-2013 Specifications and test procedures for PM10 and PM2.5 sampler regulated by Ministry of Environmental Protection.

    2. 6-10 concentration times.

    3. High output flow: up to 40-60L/min.

    4. 0.3 m³ chamber: Animal capacity: up to 40 rats/mice (single cage per rat/mouse)
    1 m³ chamber: Animal capacity: up to 96 rats/mice (single cage per rat/mouse).

    Application

    Relationship studies between environmental particulate pollution and human health.

    Animal haze pathogenesis modeling.

    Modeling, pathogenesis and drug intervention mechanism of asthma, airway hyperresponsiveness, chronic obstructive pulmonary disease, pulmonary fibrosis, acute/neonatal respiratory distress syndrome and acute pulmonary injury.

    Working Principle

    Air passes through the impact cutter, where particles larger than 2.5μm in diameter are removed, leaving only PM2.5 particles. The air then passes through a two-stage slit virtual impactor, which separates particles below 0.1μm, thereby concentrating the PM2.5 fraction. The concentrated PM2.5 then enters the dilution system, where it is mixed with dilution air before entering the whole-body exposure system.
    1. The PM2.5 cutting head uses a two-stage cut at 10μm and 2.5μm to remove particles larger than these respective sizes from the air, ensuring effective cut-off performance.
    2. The system employs a slit-type virtual impactor, which effectively ensures cut-off performance while minimizing particle loss.

    Routine Maintenance

    1.Regularly clean the insect screen of the impactor cutter. It is recommended to replace it once per week.
    2.Regularly clean the impaction plate of the impactor cutter. Under normal use, it is recommended to replace it once per week.
    3.If the differential pressure in the whole-body exposure system is found to be too high, please clean the slit-type virtual impactor. When cleaning, please note: Do not strike the slit nozzle with hard objects, and DO NOT use acidic or alkaline cleaning agents!

    Specification

    Item

    Model

    Specification

    PM2.5 Online Enriched Rodent Whole-body Exposure System

    HRH-PM186

    0.3cbm: number of test animals: up to 40 rats (single cage for single animal)

    PM2.5 Online Enriched Rodent Whole-body Exposure System

    HRH-PM286

    1cbm: number of test animals: up to 96 rats (single cage for single animal)

    Standards

    HJ 93-2013 Specifications and test procedures for PM10 and PM2.5 sampler

    OECD FDA GLP

    Make An AppointmentLEAVE YOUR MESSAGE