PM2.5 Online Enriched Rodent Whole-body Exposure System from China Suppliers and Factory for Health Research
Features
Meets HJ93-2013 specifications and test procedures for PM10 and PM2.5 samplers regulated by the Ministry of Environmental Protection.
Enables 6 to 10 concentration times for enhanced particulate delivery.
Delivers consistent high flow capacity ranging from 40 up to 60 L/min.
0.3 m³ chamber: up to 40 rats/mice.
1 m³ chamber: up to 96 rats/mice (single cage per animal).
Application
Relationship studies between environmental particulate pollution and human health.
Animal haze pathogenesis modeling and environmental toxicological evaluation.
Modeling, pathogenesis, and drug intervention mechanism of asthma, airway hyperresponsiveness, chronic obstructive pulmonary disease (COPD), pulmonary fibrosis, acute/neonatal respiratory distress syndrome (ARDS/NRDS), and acute pulmonary injury.
Working Principle
Air passes through the impact cutter, where particles larger than 2.5μm in diameter are removed, leaving only PM2.5 particles. The air then passes through a two-stage slit virtual impactor, which separates particles below 0.1μm, thereby concentrating the PM2.5 fraction. The concentrated PM2.5 then enters the dilution system, where it is mixed with dilution air before entering the whole-body exposure system.
- Cut-Off Efficiency: The PM2.5 cutting head uses a two-stage cut at 10μm and 2.5μm to remove particles larger than these respective sizes from the air, ensuring effective cut-off performance.
- Minimal Loss: The system employs a slit-type virtual impactor, which effectively ensures cut-off performance while minimizing particle loss.
Routine Maintenance
Regularly clean the insect screen of the impactor cutter. It is recommended to replace it once per week.
Regularly clean the impaction plate of the impactor cutter. Under normal use, it is recommended to replace it once per week.
Specification
| Item | Model | Specification |
|---|---|---|
| PM2.5 Online Enriched Rodent Whole-body Exposure System | HRH-PM186 | 0.3cbm: number of test animals: up to 40 rats (single cage for single animal) |
| PM2.5 Online Enriched Rodent Whole-body Exposure System | HRH-PM286 | 1cbm: number of test animals: up to 96 rats (single cage for single animal) |
Standards
HJ 93-2013 Specifications and test procedures for PM10 and PM2.5 sampler
Frequently Asked Questions (FAQ)
Which standard does the PM2.5 sampler comply with?
The PM2.5 sampler's cutting size and collection efficiency strictly meet the requirements set forth by HJ93-2013: Specifications and test procedures for PM10 and PM2.5 sampler, regulated by the Ministry of Environmental Protection.
What are the animal capacities for the HRH-PM186 and HRH-PM286 models?
The HRH-PM186 (0.3 m³ chamber) accommodates up to 40 rats or mice with individual cages. The HRH-PM286 (1 m³ chamber) accommodates up to 96 rats or mice, also in individual single cages.
What concentration efficiency and flow rates can the system produce?
The system achieves an enrichment concentration of 6 to 10 times, providing a stable high-output flow rate ranging from 40 to 60 L/min.
How does the two-stage separation and concentration process work?
Air first moves through a two-stage cutting head (10μm and 2.5μm) to remove all particulate matter exceeding 2.5μm. The remaining PM2.5 air stream passes into a two-stage slit virtual impactor that strips out particles below 0.1μm, concentrating the PM2.5 fraction before mixing it with dilution air for whole-body exposure.
What is the recommended routine maintenance schedule?
Both the insect screen and the impaction plate of the impactor cutter should be regularly cleaned and replaced once per week under normal operating conditions.
What should be avoided when cleaning the slit-type virtual impactor?
If high differential pressure requires cleaning the slit-type virtual impactor, never strike the slit nozzle with hard objects, and never use acidic or alkaline cleaning agents, as this can damage precision parts.