Pulmonary Function Testing System for Rodents - China Suppliers & Factory for Inhalation Toxicity Testing
Features
- Real-time monitoring of rodent breathing parameters while performing exposure tests.
- Easy to operate no need surgery.
- Same rodent comparison before and after drug.
- Suitable for long-term tracking research.
- Applicable to mice, rats, guinea pigs, etc.
Application
Rodent Physiology Studies, Rodent Screening, Drug Safety Assessment.
Major Components
-
1. Control cabinetThe control cabinet mainly consists of a data acquisition card and a linear vacuum pump, which is used to collect plethysmograph signals detected by sensors and provide negative pressure airflow for ventilation at a certain flow rate. The detected signals are transmitted to data analysis software via a USB cable connected to the computer.
-
2. Animal plethysmographThe animal plethysmograph is used to hold animals to be tested, which shall be kept dry inside before use and cleaned up in time after use.
-
3. Pressure sensorThe pressure sensor is used for detecting pressure changes caused by animal breathing in plethysmographs. It is connected to an animal plethysmograph and control cabinet.
-
4. DesiccantDesiccant is connected between ventilation ports among the plethysmograph and the control cabinet, which is used for drying gas extracted from the plethysmograph. The desiccant in the filter adopts silica gel with a moisture indicator, which needs to be replaced when it turns pink.
-
5. Data analysis systemThe data analysis system is a multifunctional system of data acquisition, analysis, display and storage, specially design for the WBP system.
Specification
| Parameters | Meaning |
| Ti | Inspiratory time (ms) |
| Te | Expiratory time (ms) |
| f | Respiratory rate (bpm) |
| TV | Tidal volume (mL) |
| MV | Minute ventilation (mL) |
| RT | Relaxation time (ms) |
| EV | Expiratory volume (mL) |
| PIF | Peak inspiratory flow (mL/min) |
| PEF | Peak expiratory flow (mL/min) |
| EEP | End-expiratory pause (ms) |
| Tbox | Body box temperature (°C) |
| Tbody | Animal body temperature (°C) |
| Patm | Atmospheric pressure (mmHg) |
| VCF | Correction factor |
| Penh | Enhanced pause / bronchoconstriction index |
| EF50 | 50% expiratory flow rate (mL/min) |
| EIP | End-inspiratory pause (ms) |
Data Analysis Performance
1. Real-time collection and analysis curve parameters, display the average value of respiratory parameters within 5s.
2. Historical test data query, playback at the fastest 32x speed.
3. Analysis data can be exported to Excel.
Specification
| Item | Channel 4 | Channel 8 |
| Communication port | USB type-D | USB type-D |
| Sensor range | ±2.5 H2O | ±2.5 H2O |
| Power supply | 220VAC 50Hz | 220VAC 50Hz |
| Weight | 13.3kg | 15.5kg |
| Dimensions | 618x320x230mm | 618x320x230mm |
Working Conditions
Temp: 0℃~60℃
Humidity: 5%~95% (non-condensing)
Humidity: 5%~95% (non-condensing)
Storage Conditions
Temp: -20℃~70℃
Humidity: 5%~95% (non-condensing)
Humidity: 5%~95% (non-condensing)
Conditions
[1] Wang Guanlin, Zhai Zizhao, Wang Wenhao, et al. Tailored Borneol-Modified Lipid Nanoparticles Nasal Spray for En-hanced Nose-to-Brain Delivery to Central Nervous System Diseases. ACS Nano, 2024, https://doi.org/10.1021/acsna-no.4c08279.(IF 15.8)
[2] Linjing Wu, Wenhao Wang, Mengqin Guo, et al. Inhalable iron redox cycling powered nanoreactor for amplified ferro-ptosis-apoptosis synergetic therapy of lung cancer. Nano Res. 2024, https://doi.org/10.1007/s12274-024-6455-2. (IF 9.5)
Frequently Asked Questions (FAQ)
What parameters can be monitored in real-time using this system?
The system monitors key respiratory parameters in real-time, including Inspiratory time (Ti), Expiratory time (Te), Respiratory rate (f), Tidal volume (TV), Minute ventilation (MV), and more.
Is surgery required to operate the rodent plethysmograph?
No, the system is designed to be easy to operate and does not require surgery, ensuring a non-invasive testing process for the animals.
Which animals are suitable for this WBP system?
The system is highly applicable to mice, rats, guinea pigs, and other similar small rodents.
How can I export the test data for further analysis?
All analyzed data can be easily exported directly to Excel spreadsheets for convenient post-test analysis and reporting.
What are the required working and storage environmental conditions?
The working conditions require a temperature of 0℃ to 60℃, while storage conditions require -20℃ to 70℃. Both require a humidity range of 5% to 95% (non-condensing).