Pulmonary Function Testing System for Rodents - Quality Supply from China Suppliers and Factory for Inhalation Toxicity Tests
Features
- Real-time monitoring of rodent breathing parameters while performing exposure tests.
- Easy to operate, no surgery required.
- Same rodent comparison before and after drug administration.
- Suitable for long-term tracking research.
- Applicable to mice, rats, guinea pigs, etc.
Application
Major Components
Specification (Parameters)
| Parameters | Meaning |
|---|---|
| Ti | Inspiratory time (ms) |
| Te | Expiratory time (ms) |
| f | Respiratory rate (bpm) |
| TV | Tidal volume (mL) |
| MV | Minute ventilation (mL) |
| RT | Relaxation time (ms) |
| EV | Expiratory volume (mL) |
| PIF | Peak inspiratory flow (mL/min) |
| PEF | Peak expiratory flow (mL/min) |
| EEP | End-expiratory pause (ms) |
| Tbox | Body box temperature (°C) |
| Tbody | Animal body temperature (°C) |
| Patm | Atmospheric pressure (mmHg) |
| VCF | Correction factor |
| Penh | Enhanced pause / bronchoconstriction index |
| EF50 | 50% expiratory flow rate (mL/min) |
| EIP | End-inspiratory pause (ms) |
Data Analysis Performance
- Real-time collection and analysis curve parameters, display the average value of respiratory parameters within 5s.
- Historical test data query, playback at the fastest 32x speed.
- Analysis data can be exported to Excel.
Specification (Channels)
| Item | Channel 4 | Channel 8 |
|---|---|---|
| Communication port | USB type-D | USB type-D |
| Sensor range | ±2.5 H2O | ±2.5 H2O |
| Power supply | 220VAC 50Hz | 220VAC 50Hz |
| Weight | 13.3kg | 15.5kg |
| Dimensions | 618x320x230mm | 618x320x230mm |
Humidity: 5%~95% (non-condensing)
Humidity: 5%~95% (non-condensing)
Conditions (Publications)
Frequently Asked Questions
Q: Which animal species are suitable for this WBP system?
A: The system is designed for and widely applicable to small laboratory animals, specifically mice, rats, and guinea pigs.
Q: Is surgical preparation required for the animals?
A: No, the system is designed for non-invasive testing. It is easy to operate and requires no surgery, which makes it ideal for long-term tracking research.
Q: What is the role of the desiccant and when should it be replaced?
A: The desiccant dries the gas extracted from the plethysmograph. It uses silica gel with a moisture indicator, which changes color and must be replaced when it turns pink.
Q: Can I perform same-animal comparison tests?
A: Yes, the system supports same-rodent baseline comparison before and after drug administration, ensuring highly reliable experimental control.
Q: What data analysis capabilities does the software provide?
A: The software offers real-time curve parameter collection (showing average values every 5s), historical test data query with up to 32x speed playback, and direct export of data to Excel.