Pulmonary Function Testing System for Rodents - Top China Suppliers & Factory for Inhalation Toxicity Testing
Features
- Real-time monitoring of rodent breathing parameters while performing exposure tests.
- Easy to operate, no need for surgery.
- Same rodent comparison before and after drug administration.
- Suitable for long-term tracking research.
- Applicable to mice, rats, guinea pigs, etc.
Application
This system is widely applied in various preclinical research fields:
Major Components
1 Control cabinet
The control cabinet mainly consists of a data acquisition card and a linear vacuum pump, which is used to collect plethysmograph signals detected by sensors and provide negative pressure airflow for ventilation at a certain flow rate. The detected signals are transmitted to data analysis software via a USB cable connected to the computer.
2 Animal plethysmograph
The animal plethysmograph is used to hold animals to be tested, which shall be kept dry inside before use and cleaned up in time after use.
3 Pressure sensor
The pressure sensor is used for detecting pressure changes caused by animal breathing in plethysmographs. It is connected to an animal plethysmograph and control cabinet.
4 Desiccant
Desiccant is connected between ventilation ports among the plethysmograph and the control cabinet, which is used for drying gas extracted from the plethysmograph. The desiccant in the filter adopts silica gel with a moisture indicator, which needs to be replaced when it turns pink.
5 Data analysis system
The data analysis system is a multifunctional system of data acquisition, analysis, display and storage, specially designed for the WBP system.
Parameter Specification
| Parameters | Meaning |
|---|---|
| Ti | Inspiratory time (ms) |
| Te | Expiratory time (ms) |
| f | Respiratory rate (bpm) |
| TV | Tidal volume (mL) |
| MV | Minute ventilation (mL) |
| RT | Relaxation time (ms) |
| EV | Expiratory volume (mL) |
| PIF | Peak inspiratory flow (mL/min) |
| PEF | Peak expiratory flow (mL/min) |
| EEP | End-expiratory pause (ms) |
| Tbox | Body box temperature (°C) |
| Tbody | Animal body temperature (°C) |
| Patm | Atmospheric pressure (mmHg) |
| VCF | Correction factor |
| Penh | Enhanced pause / bronchoconstriction index |
| EF50 | 50% expiratory flow rate (mL/min) |
| EIP | End-inspiratory pause (ms) |
Data Analysis Performance
- Real-time collection and analysis of curve parameters, displaying the average value of respiratory parameters within 5 seconds.
- Historical test data query, with playback speeds up to 32x.
- Analysis data can be seamlessly exported to Excel.
System Specifications
| Item | Channel 4 | Channel 8 |
|---|---|---|
| Communication port | USB type-D | USB type-D |
| Sensor range | ±2.5 H2O | ±2.5 H2O |
| Power supply | 220VAC 50Hz | 220VAC 50Hz |
| Weight | 13.3kg | 15.5kg |
| Dimensions | 618x320x230mm | 618x320x230mm |
Environmental Conditions
Working Conditions
Temp: 0℃ ~ 60℃
Humidity: 5% ~ 95% (non-condensing)
Humidity: 5% ~ 95% (non-condensing)
Storage Conditions
Temp: -20℃ ~ 70℃
Humidity: 5% ~ 95% (non-condensing)
Humidity: 5% ~ 95% (non-condensing)
Publications & Citations
- [1] Wang Guanlin, Zhai Zizhao, Wang Wenhao, et al. Tailored Borneol-Modified Lipid Nanoparticles Nasal Spray for Enhanced Nose-to-Brain Delivery to Central Nervous System Diseases. ACS Nano, 2024, https://doi.org/10.1021/acsnano.4c08279. (IF 15.8)
- [2] Linjing Wu, Wenhao Wang, Mengqin Guo, et al. Inhalable iron redox cycling powered nanoreactor for amplified ferroptosis-apoptosis synergetic therapy of lung cancer. Nano Res. 2024, https://doi.org/10.1007/s12274-024-6455-2. (IF 9.5)
Frequently Asked Questions
Do rodents require surgery to undergo breathing tests with this system?
No, the system is designed to be easy to operate and does not require surgery, ensuring non-invasive, real-time monitoring of rodent breathing parameters.
Which animal species are compatible with the plethysmograph?
The animal plethysmograph is applicable to mice, rats, guinea pigs, and other similar rodents.
What parameters can the data analysis system acquire and calculate?
The system tracks multiple parameters, including Ti (Inspiratory time), Te (Expiratory time), f (Respiratory rate), TV (Tidal volume), MV (Minute ventilation), RT (Relaxation time), EV (Expiratory volume), PIF/PEF (Peak flows), EEP/EIP (Pauses), temperature (Tbox, Tbody), Patm, VCF, and the Penh (Enhanced pause / bronchoconstriction index).
How does the desiccant filter function, and when should it be replaced?
The desiccant is placed between the ventilation ports of the plethysmograph and the control cabinet to dry the extracted gas. It uses silica gel with a moisture indicator, which must be replaced when it turns from its original color to pink.
What are the weight and dimension differences between the 4-channel and 8-channel models?
Both models share the same dimensions (618x320x230mm) and interface ports (USB type-D). However, the 4-channel model weighs 13.3kg, whereas the 8-channel model weighs 15.5kg.
Can I export and play back historical test data?
Yes, the system allows historical test data queries with playback speeds up to 32x, and you can export the collected analysis data to Excel format.

