Pulmonary Function Testing System for Rodents - Trusted China Suppliers and Factory for Inhalation Toxicity Testing
Features
Application
Rodent Physiology Studies, Rodent Screening, Drug Safety Assessment.
Major Components
The control cabinet mainly consists of a data acquisition card and a linear vacuum pump, which is used to collect plethysmograph signals detected by sensors and provide negative pressure airflow for ventilation at a certain flow rate. The detected signals are transmitted to data analysis software via a USB cable connected to the computer.
The animal plethysmograph is used to hold animals to be tested, which shall be kept dry inside before use and cleaned up in time after use.
The pressure sensor is used for detecting pressure changes caused by animal breathing in plethysmographs. It is connected to an animal plethysmograph and control cabinet.
Desiccant is connected between ventilation ports among the plethysmograph and the control cabinet, which is used for drying gas extracted from the plethysmograph. The desiccant in the filter adopts silica gel with a moisture indicator, which needs to be replaced when it turns pink.
The data analysis system is a multifunctional system of data acquisition, analysis, display and storage, specially designed for the WBP system.
Specification (Parameters)
| Parameters | Meaning |
|---|---|
| Ti | Inspiratory time (ms) |
| Te | Expiratory time (ms) |
| f | Respiratory rate (bpm) |
| TV | Tidal volume (mL) |
| MV | Minute ventilation (mL) |
| RT | Relaxation time (ms) |
| EV | Expiratory volume (mL) |
| PIF | Peak inspiratory flow (mL/min) |
| PEF | Peak expiratory flow (mL/min) |
| EEP | End-expiratory pause (ms) |
| Tbox | Body box temperature (°C) |
| Tbody | Animal body temperature (°C) |
| Patm | Atmospheric pressure (mmHg) |
| VCF | Correction factor |
| Penh | Enhanced pause / bronchoconstriction index |
| EF50 | 50% expiratory flow rate (mL/min) |
| EIP | End-inspiratory pause (ms) |
Data Analysis Performance
- Real-time collection and analysis of curve parameters, displaying the average value of respiratory parameters within 5s.
- Historical test data query, with playback speeds up to 32x.
- Analysis data can be easily exported to Excel.
Specification (Hardware)
| Item | Channel 4 | Channel 8 |
|---|---|---|
| Communication port | USB type-D | USB type-D |
| Sensor range | ±2.5 H2O | ±2.5 H2O |
| Power supply | 220VAC 50Hz | 220VAC 50Hz |
| Weight | 13.3kg | 15.5kg |
| Dimensions | 618x320x230mm | 618x320x230mm |
Environmental Conditions
Humidity: 5% ~ 95% (non-condensing)
Humidity: 5% ~ 95% (non-condensing)
Literature Citations & Conditions
Frequently Asked Questions (FAQ)
Q Which animal species is this system designed for?
This system is designed for rodent physiology studies and is highly applicable to mice, rats, guinea pigs, and other similar small rodents.
Q Is surgery required to monitor the rodents?
No, the system is completely non-invasive and easy to operate. There is no need to perform surgery on the animals to gather breathing parameters.
Q Can the system track long-term drug effects on the same animal?
Yes, it is designed for long-term tracking research, allowing researchers to easily perform same-rodent comparisons before and after drug administration.
Q What functions does the data analysis software offer?
The software supports real-time collection and curve analysis (averaging parameters every 5s), historical test data query with up to 32x playback speed, and data export to Excel format.
Q When should the desiccant in the filter be replaced?
The desiccant uses silica gel with a moisture indicator. It needs to be replaced when the color turns pink, ensuring the plethysmograph remains dry.
Q What are the system's operational and storage limits?
The working conditions require temperatures between 0℃ and 60℃. For storage, the temperature should be kept between -20℃ and 70℃. Both conditions require a non-condensing humidity level of 5% to 95%.