Request a Quote
Leave Your Message

Rodent Gas Exposure Chamber

Model HRH-CSED-K Rodent Gas Exposure Chamber can be used to conduct acute and chronic rodent toxicity exposure tests under environments of toxic and hazardous gases, as well as toxic and hazardous gas exposure tests of rodents under high and low oxygen/pressure/mixed atmosphere.

    Features

    With abundant gas sampling ports and powerful sampling expansion functions, gases (e.g., smoke, formaldehyde, benzene, radon, carbon dioxide and carbon monoxide) can be used as poisoning gases. 

    The instrument can be used for acute exposure, chronic exposure, low pressure, high pressure, low oxygen, high oxygen and other gas exposure tests.

    Pressure difference, oxygen concentration, poisonous gas concentration and other indexes in exposure environment can be precisely controlled.

    All parameters are real-time monitored, their values and curves are dynamically displayed. Real-time alarm and record, historical data and curves are automatically saved. Historical report query, printing and data exporting are simple.

    Application

    Environmental Toxicity. Drug Toxicity. Radiological Toxicity.

    Food Toxicity. Industrial Toxicity. Veterinary Toxicity.

    Specification

    Chamber size (LxWxH): 780mm x 450mm x 530mm, volume 186L

    Overall dimensions (LxWxH): 1260mm x 672mm x 724mm (excluding accessories e.g. air compressor)

    Number of experimental animals:80 mice or 10 rats

    Animal cage material: SS304

    Temperature detection: resolution 0.1℃,measuring range 0-100℃;

    Humidity detection resolution: 1%, measuring range 0-100%RH.

    Differential pressure detection: measuring range -1000-1000Pa.

    Oxygen detection resolution: 0.1%, measuring range 0-25%.

    Carbon dioxide detection resolution: 0.01%, measuring range 0-5%.

    Dilution flow rate 30L/min, flow control range: 2%-100%F.S., accuracy: ±1.0%F.S.

    Extraction flow rate 60L/min, flow control range: 5%-100%F.S., accuracy: ±1.0%F.S.

    Differential pressure control range negative pressure 0-200Pa, control accuracy ±10Pa.

    Standards

    OECD Guidelines

    ① OECD TG 403 Acute Inhalation Toxicity (2009).

    ② OECD TG 436 Acute Inhalation Toxicity. Acute Toxic Class Method (2009).

    ③ OECD TG 412 28d Sub-acute inhalation (2018).

    ④ OECD TG 413 90d Sub-chronic inhalation (2018).

    OECD

    Typical Users

    Institute of Radiation Medicine, Academy of Military Medical Sciences, Academy of Military Sciences
    Institute of Environmental Medicine and Occupational Medicine, Academy of Military Medical Sciences
    Beijing Tobacco Factory
    Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology
    Yunnan Provincial Hospital of Oncology
    Sichuan Exit-Entry Inspection and Quarantine Bureau
    Technology Center of Ningbo Entry Exit Inspection and Quarantine Bureau
    Sun Yat-sen University
    The second Hospital of Hebei Medical University
    Guangxi University of Science and Technology
    Naval Medical University
    Dali University
    Hebei North University
    Xinjiang Medical University
    Hebei Medical University
    PLA Center for Disease Control and Prevention
    Henan University
    Shanghai Municipal Center for Disease Control & Prevention
    Chemical Defense Institute, Academy of Military Sciences, PLA

    Make An AppointmentLEAVE YOUR MESSAGE