High-precision instrumentation designed to automate sample preparation, evaluate occupational exposure risks, and analyze toxic components within boiler and turbine insulation materials.
Streamlines the extraction of organic binders, flame retardants, and chemical contaminants from degraded boiler refractory insulation samples with high reproducibility.
Designed for aerodynamic particle sizing of airborne fibers and dust released during turbine insulation removal, ensuring accurate EHS risk assessment.
Generates stable, dry dust aerosols from insulation materials, ideal for testing the efficiency of safety barriers and industrial containment systems.
Monitors respirable dust and fiber concentration levels in real-time during boiler maintenance outages to protect field technicians.
Thermal insulation in power generation plants, specifically surrounding high-pressure boilers and steam turbines, operates under extreme environmental stress. Over decades of operation, materials such as calcium silicate, mineral wool, and refractory ceramic fibers (RCFs) undergo severe thermal degradation, mechanical vibration, and chemical infiltration. When maintenance cycles require the removal, repair, or inspection of these insulation systems, they pose significant environmental health and safety (EHS) risks due to the potential release of hazardous airborne fibers, including legacy asbestos and crystalline silica.
Effective maintenance and risk mitigation begin with rigorous chemical and physical characterization of the insulation materials. Sample preparation stands as the single most critical phase of this analytical workflow. Without standardized, contamination-free sample preparation, downstream analytical techniques—such as X-ray diffraction (XRD) for crystalline phase determination, gas chromatography-mass spectrometry (GC-MS) for organic binder degradation, and scanning electron microscopy (SEM) for fiber morphology—cannot yield reliable quantitative data.
Globally, the power generation sector is undergoing a dual transition: extending the operational lifespan of existing thermal power plants while adhering to increasingly stringent occupational safety regulations. The maintenance of boilers and turbines requires periodic "de-lagging" (removing insulation jackets). This process generates massive quantities of fugitive dust. EHS regulations enforced by bodies like OSHA and the European Chemicals Agency (ECHA) mandate strict monitoring of respirable crystalline silica (RCS) and synthetic vitreous fibers (SVFs).
Consequently, utility operators and specialized maintenance contractors are investing heavily in advanced diagnostic testing. Before any physical dismantling occurs, core insulation samples are extracted and sent to analytical laboratories. The industry is rapidly moving away from manual, error-prone sample preparation methods toward automated, high-throughput systems that minimize laboratory technician exposure to hazardous dust while ensuring high extraction recovery rates for target chemical compounds.
Three major trends are currently reshaping the field of sample preparation for industrial insulation maintenance:
Inside the boiler penthouse, refractory linings are exposed to corrosive flue gases and temperatures exceeding 1000°C. Over time, chemical reactions alter the mineral structure of the insulation, potentially forming hazardous crystalline silica phases (like cristobalite). Standard sample preparation involves grinding the tough refractory ceramic matrix into a fine, homogeneous powder. Automated milling and extraction systems ensure the sample is reduced to a uniform particle size without altering the mineral phases through frictional heat, enabling precise quantitative XRD analysis to assess the hazard level before maintenance crews enter.
Steam turbines operate under high vibration and thermal cycling. The insulation blankets wrapping the turbine casing often absorb leaked lubricating oils and hydraulic fluids, which decompose under high heat into toxic polycyclic aromatic hydrocarbons (PAHs) and other organic residues. Preparing these oily, fibrous samples for gas chromatography requires advanced extraction protocols. Utilizing automated QuEChERS (Quick, Easy, Cheap, Effective, Rugged, Safe) methods allows for rapid extraction of organic contaminants from the complex fibrous matrix, providing rapid turnaround times during critical plant outages.
Beijing HuirongheTechnology Co., Ltd., (overseas brand "HRHINS") founded in 2010 with a registered capital of 10 million yuan, is located in the Beijing Economic-Technological Development Area. The company specializes in the R&D, production, sales, and technical services for inhalation toxicity, genetic toxicity, inhaler testing, aerosol detection, and lab automation systems.
HRHINS has been recognized as a National High-tech Enterprise and designated as a Beijing Municipal Corporate Science and Technology R&D Institution. Additionally, it has received honors such as being a Beijing "Specialized, Refined, Unique, and Innovative" SME, a China Manufacturing Champion Enterprise, and a Beijing Intellectual Property Demonstration Enterprise.
Further accolades include being named a National Intellectual Property Advantage Enterprise in 2019, a National "Little Giant" SME (the first in the aerosol scientific instrument field) in 2022, and a recipient of the Second Prize in Scientific and Technological Progress from the Tianjin Municipal Government in 2022.
The company occupies over 3000sqm of offices, R&D center and workshops.
HRHINS holds certifications for the ISO 9001:2015 Quality Management System, ISO 14001:2015 Environmental Management System, ISO 45001:2018 Occupational Health and Safety Management System, and GB/T 29490-2013 Intellectual Property Management System.
In 2018, HRHINS supported the establishment of the Respiratory Toxicology Committee of the Chinese Society of Toxicology and became its founding sponsor. That same year, the company also gained council membership in several prestigious organizations, including the Chinese Society of Toxicology, the Chinese Environmental Mutagen Society, and the Zhongguancun New Bio-pharmaceutical Industry Alliance.

HRHINS has developed over 60 innovative instruments, including aerosol generators, inhalation systems, fully automated QuEChERS system, multi-stage cascade impactor, and breathing simulator, etc.
The aerosol toxicity instrument line offers a complete suite for studies involving rats, mice, guinea pigs, ferrets, rabbits, dogs, and monkeys. Supported exposure methods are equally comprehensive, covering nose-head, whole-body, airborne infection, and in vitro cell culture exposures.
Crucially, all products—from aerosol generation and detection to sampling and system control—are based on independent intellectual property.
These solutions are widely employed by GLP laboratories, safety assessment centers, universities, research institutions, and hospital respiratory departments. Thanks to their superior quality and reliable after-sales support, our products have earned the trust of users both in China and internationally.
Explore our full range of scientific instruments designed to support aerosol generation, inhalation toxicology, and automated sample preparation for industrial safety.
Optimized for rapid extraction of organic binders, PAHs, and residues from degraded turbine insulation blankets.
Accurately segregates airborne dust particles by aerodynamic size to identify high-risk respirable fractions.
Generates highly stable and reproducible dust concentrations from solid insulation materials for filter media testing.
Simulates human respiration profiles to evaluate the efficiency of respiratory protective equipment (PPE) against insulation fibers.
Designed for in vivo inhalation toxicity studies of synthetic vitreous fibers on animal models under controlled environments.
Enables direct deposition of aerosolized insulation fibers onto lung cell cultures at the air-liquid interface.
Streamlines reagent addition and dilution steps in chemical analysis of toxic components in thermal insulation.
Collects large volumes of airborne particulate matter during boiler de-lagging operations for gravimetric analysis.