Single Concentration Cell Culture System
Application
1.Smoke Inhalation and Health Studies.
2.Environmental and Health Effects of Chemical Pesticides.
3.Impacts on Environment and Health of Air Particulate Matter and Microorganisms.
4.Health Evaluation of Indoor Gases.
5.Research on Biosafety Evaluation of Nanomaterials.
6.Health Impacts of Industrial Chemicals.
7.Research on Chronic Obstructive Pulmonary Disease, Lung Cancer and Other Related Diseases.
8.Pharmaceutical Product Related Research.
Features
1.Direct exposure to monolayer cultured cells or bacteria.
2.ALI- Air-Liquid interface exposure that exactly mimics the in vivo environment.
3.The aerosol is uniformly distributed within the exposure chamber and flows at a constant rate.
4.Ensure consistency of flow rate and concentration for the same concentration.
5.The biosafety cabinet provides a super clean laboratory environment, with all parts of the exposed module removable for sterilization.
6.Aerosol mass concentration detector could adjust and precisely control the concentration of flue gases or aerosol.
7.Flow control accuracy up to ±1.5%F.S.
8.With high efficiency, up to 9 exposure units in 3 concentrations can be conducted simultaneously.
9.Thermostatic water bath temperature control accuracy of ±0.3℃.
10.Industrial controller has touch screen, stable performance, small and delicate appearance.
11.User-friendly HMI and highly intelligent control software with easy operation.
12.Effectively reduce noise by adopting a silent air compressor.
13.The module was reasonably simplified, adopting mature modules to ensure the reliability of test accuracy.
Technical Parameters
1. ALI – Air-Liquid Interface exposure.
2. Single-well exposure flow rate: 5–20 mL.
3. Online monitoring of aerosol concentration.
4. Flow control accuracy: ±1% F.S..
5. Compatible with quartz crystal microbalance.
6. Compatible with 6-well and 12-well Transwell inserts.
7. Water bath temperature control accuracy: ±0.3°C.
8. Optional clean bench / biological safety cabinet to provide a clean exposure environment.
Components
1. Liquid Aerosol Generator
a. Aerosol particle size distribution is MMAD1-3μm, GSD1.5-3 which meets OECD TG 403 Acute Inhalation Toxicity (2009) and other standards.
b. Atomized by compressed air heatlessly, liquid samples can be generated into even and stable aerosol.
c. Applicable to various water-soluble and oil-soluble liquid samples and suspensions with some stable fine particles.
d. Applicable to aerosol generating from rare samples in large dose.
e. Applicable to microbial aerosol generation with minimal damage on microorganisms, and can be applied to animal inhalation infection models and related research.
f. Made of medical-grade SS316L, PTFE and high borosilicate glass, which are anti-corrosion and can be autoclaved.
| Model | Spec | Rated gas flow |
| HRH-WAG1 | 1 hole | 2L/min |
| HRH-WAG3 | 3 holes | 6L/min |
| HRH-WAG6 | 6 holes | 12L/min |
| HRH-WAG1M | Micro liquid 1 hole | 2L/min |
| HRH-WAG3M | Micro liquid 3 holes | 6L/min |
| HRH-WAG6M | Micro liquid 6 holes | 12L/min |
| HRH-WAG12 | 12 holes | 24L/min |
| HRH-WAG24 | 24 holes | 48L/min |

2. VOC Metered Gas Generator (Optional)
a. VOC metered gas generator is an instrument that can quantitatively and rapidly evaporate volatile organic compounds (e.g., alcohol, formaldehyde, etc.) to produce gas with controlled concentration.
b. Quantification is accurate, continuous and stable. Volatilization rate: 0 ~ 5ml/min.
c. Flow rate: 0 ~ 20L/min.
d. Heating temp: 20 ~ 60℃.

3. Single-Channel Intelligent Smoking Generator (Optional)
a. Complied with ISO3308 smoking standard, the machine can load with two cigarettes simultaneously, switch manual /auto mode to realize continuous smoking of bulk cigarettes, and also can be connected to exposure system seamlessly for standard cigarettes poisoning.
b. Enable deep smoking mode.
c. Easy to disassemble and clean as the smoking barrel is placed outside the machine.
d. Special software with settable functions of flow rate, smoking time, interval, frequency, number of suctions, flow compensation, etc.
e. Pressure drop: pressure difference between cigarette butts and suction source is less than 200Pa.
f. Standard smoking duration: 2±0.1s.
g. Smoking capacity: 15~60ml, Control accuracy: ±0.1ml.
h. Standard volume: 35±0.1 ml, Deep smoking: 55±0.1 ml.
i. Smoking frequency: 10~240s adjustable, standard frequency is 60s.
j. Center distance of burner reactor :> 50mm.

4. Ten-channel Fully Automated Turntable Smoking Machine (Optional)
a. With automatic cigarette loading and lighting, the machine adopts international standard bell-shaped curve and settable normal smoking curve. Cigarettes can be pulled out, extinguished and replenished automatically after burning out. The burning length of cigarettes can be set. The machine can also be connected to exposure system seamlessly for standard cigarette poisoning.
b. Complied with ISO3308 smoking standard.
c. Enable deep smoking mode.
d. Cigarette bin capacity: 200 (midway feeding supported).
e. Special software with settable functions of flow rate, smoking time, interval, frequency, number of suctions, flow compensation, etc..
f. Pressure drop: pressure difference between cigarette butts and suction source is less than 200Pa.
g. Standard smoking duration: 2±0.1s.
h. Smoking capacity: 15~60ml, Control accuracy: ±0.1ml.
i. Standard volume: 35±0.1 ml, Deep smoking: 55±0.1ml.
j. Smoking frequency: 30~240s adjustable, standard frequency is 60s.

5. Single-channel E-Cigarette Smoking Machine (Optional)
a. Compliant with E-cigarette smoking test methods of domestic and international standards (e.g., France XP D90-300-3), E-cigarette smoking machine adopts precise mechanical movement and electronic control module. It can also be used for E-cigarette gas trapping analysis and gas poisoning tests.
b. Smoking capacity 15-60ml.
c. Smoking frequency 10-240s.
d. E-cigarette tilt angle 0-90° to ensure complete heating of tobacco oil.
e. Strong adaptability, sealed adapter can be customized according to different mouthpieces in different shapes.
f. Two electronic cigarettes can be loaded at the same time, switching automatically to meet the requirements of long-time experiments.
g. Various vaping curves can be realized to meet various experimental requirements.



6. Liquid Flow Controller
a. Used for online liquid samples supplying.
b. Flow Range: 0.2 ~ 10ml/min.
c. Hose Size: 2×1mm.
d. Speed Range: 0 .1 ~ 80rpm.
e. Speed Resolution: 0.1rpm.
f. Conveying Accuracy: <0.5%.
g. Power Supply: DC24V/2A.
h. External Control Digital Communication Interface: RS485.
i. Working Environment: ambient temp 0 ~ 40℃, relative humidity<80%RH.

7.Single Concentration Cell Culture System
a.Sterile test environment: cell exposure test is conducted in BSC cabinet, which constantly provides clean and sterile air flow to isolate the working table from contact with external contamination and affect test effect and authenticity.
b.Various cell exposure modules to meet different test requirements.
c.Static and dynamic nutrient supply: nutrient is supplied to cells statically and dynamically through the nutrient supply unit to ensure a good living environment for cells.
d.Thermostatic water bath cultivation: provide constant temperature water as per setting for water bath during the test to ensure that cells are in good living condition. Control accuracy of thermostatic water bath is ±0.3℃.

8.Exposure Environment Monitor
Real-time monitoring and control of temperature, humidity, O2, and CO2 concentration during cell exposure.

9.Aerosol Mass Concentration Detector
a. Sensor: visible red laser module with near forward light scattering at wavelength 635nm.
b. Measurement range: up to 250g/m3.
c. Range mode: fixed or auto-selected.
d. Communication mode: RS485 Modbus communication.
e. Alarm: can trigger and reset alarm according to user-defined trigger threshold and time.
f. Data record: storage capacity is larger than 50,000 data points.
g. Measurement display: Real-time numerical display or graphical display.
h. Realize real-time online sampling of pre-test liquid aerosol and automatic adjustment to target value for test dose concentration via host control.

10.Quartz Balance Quality Concentration Monitor (Optional)
a. Quartz crystal oscillator frequency: 5MHz.
b. Quartz crystal diameter: 1”.
c. Crystal electrode material: chrome / gold (titanium / gold, titanium / platinum, etc.).
d. Frequency resolution: 0.01Hz.
e. Mass resolution: 0.177ng/cm2.
f. Communication: RS-232.
g. Power supply: 15W, 100/120/220/240VAC,50/60Hz.
h. Display quality change of quartz monitor crystal deposition particle matter with software control.

11. Particle Size Analyzer (Optional)
a. It is a low-flow particle size analysis sampler with inertial impact principle, used for stage sampling and weighing of aerosol particles and then calculating parameters such as MMAD and GSD, etc.
b. Sampling flow rate 0.5L/min is ideal for particle size analysis in animal exposure tests.
c. The sampler is divided into 7 stages + membrane stage, cutting particle size of each stage as below:
| Stage | Cutting Size (μm) |
| 1 | 5.1 |
| 2 | 3.1 |
| 3 | 1.9 |
| 4 | 1.2 |
| 5 | 0.77 |
| 6 | 0.50 |
| 7 | 0.33 |

12. Air Compressor
a. Flow Rate 35L/min. Max. pressure 8Bar. Storage tank capacity 30L. Dew point temp 5℃. Noise≤ 60dB. Equipped with heatless regenerative dryer.
b. Oil-free: complete oil-free design, no oil molecules in output gas, harmless to human body.
c. Super Silent: low noise, output gas pressure is smooth to reduce noise.
d. Multi-stage Filtration: cleaner and purer multi-stage gas filtration can extend the service life of instruments.
e. Anti-rust Internal Spraying: gas tank is refined by internal spraying to avoid rust contamination.
f. Safety in Use: automatic shutdown to protect and avoid burnout when machine overheats by voltage or current.
g. Automatic Start: intermittent use does not require reset.
h. Adjustable Gas Pressure: meet the requirement of different equipment.

12. Exhaust Gas Treatment System
Adopt quadruple filtration system and standard filter material for easy replacement at lower costs.

13. Silent Oil-free Air Pump: RoHs compliant, it can provide max. 7L/min pumping flow. Noise ≤ 60dB.
1.Aerosol Generation Flow Controller
Control range 0 ~ 5L, repeatability ±0.2%F.S. Measurement accuracy ±1.0%F.S. Linear accuracy±0.5%F.S. Flow controller has servo valve itself.
15. Gas Extraction Flow Controller
Control range 0 ~ 100mL, repeatability ±0.2%F.S. Measurement accuracy ±1.0%F.S. Linear accuracy±0.5%F.S. Flow controller has servo valve itself.

16.BSC cabinet: keep samples, personnel and environmentally safe.
17. Ultra-clean table: provide sample protection.

18. Commercial Computer
a. Commercial computer has superior performances in reliability, stability, weather resistance, shock resistance, water and dust resistance, interference resistance, scalability EMC compatibility, etc. Reliable hard drive guarantees data security.
b. Display: equipped with a touch screen in 21.5 inches.
c. Resolution: 1920×1080, touchable.
d. OS: Windows 7.
e. Input device: wireless mouse and keyboard.
19. Control System
Collect real-time parameters such as temp, humidity, pressure difference, oxygen concentration, carbon dioxide, and aerosol concentration. Control 5-way flow controllers of aerosol generation, dilution, sampling, carbon dioxide, and gas extraction volume. Control gas extraction pump and other automatic devices.
20. Host Software
a. Software can perform tests overall control, parameter setting, real-time monitoring and recording for environmental parameters during tests, real-time alarm and recording of abnormalities.
b. Various test data storage and access, automatically issue reports post-test, etc.




Standards
| Product | Model | Spec (port x layer) |
| Single Concentration Cell Culture System | HRH-CES1314 | 1×3 |
| Single Concentration Cell Culture System | HRH-CES1332 | 1×3 |
Standards
OECD Guidelines
① OECD TG 403 Acute Inhalation Toxicity (2009).
② OECD TG 436 Acute Inhalation Toxicity. Acute Toxic Class Method (2009).
③ OECD TG 412 28d Sub-acute inhalation (2018).
④ OECD TG 413 90d Sub-chronic inhalation (2018).

Typical Users
|
Academy of Military Medical Sciences |
China Institute for Radiation Protection |
|
Institute of Materia Medica Chinese Academy of Medical Science |
Guangxi University of Science and Technology |
|
Jiangsu Provincial Center for Disease Control and Prevention |
North China University of Science and Technology |
|
China Tobacco Quality Supervision and Inspection Center |
Shanxi Medical University |
|
Xinxiang Medical University |
Inner Mongolia Medical University |
|
China Tobacco Guangdong Industrial Corporation Limited |
Soochow University |
|
China CDC |
… |
Publications
[1] Tao Yu, Xueyan Zhang, Lei Zhong, et al. The use of a 0.20 mm particulate matter filter decreases cytotoxicity in lung epithelial cells following air-liquid interface exposure to motorcycle exhaust[J]. Environmental Pollution, 2017, 227: 287-295. http://dx.doi.org/10.1016/j.envpol.2017.04.080.
[2] Sen Zhang, Huan Chen, An Wang, et al. Genotoxicity evaluation of carbon monoxide and 1, 3-butadiene using a new joint technology — the in vitro γH2AX HCS assay combined with air-liquid interface system[J]. Toxicology Mechanisms and Methods, 2018, DOI: 10.1080/15376516.2018.1477897.
[3] Hua Chenfeng, Shang Pingping, Zhao Junwei, et al. Effects of In Vitro Mechanical Forces on Cytotoxicity and IL-8 Secretion Levels in Human Pulmonary Macrophages [J]. Public Health and Preventive Medicine, 2019, 30(5): 15–19.
[4] Wang Liyun, Liu Xingyu, Chen Lisha, et al. Harmful chemicals of heat not burn product and its induced oxidative stress of macrophages at air-liquid interface: Comparison with ultra-light cigarette[J]. Toxicology Letters, 2020, 331,200–207.
[5] Xiaobo Li, Chengcheng Zhang, Qian Bian, et al. Integrative Functional Transcriptomic Analyses Implicate Specific Molecular Pathways in pulmonary toxicity from Exposure to Aluminum Oxide Nanoparticles[J]. Nanotoxicology, 2016,10(7):957-969. Doi: 10.3109/17435390.2016.1149632.
[6] Li et al.An acetyl-L-carnitine switch on mitochondrial dysfunction and rescue in the metabolomics study on aluminum oxide nanoparticles[J]. Particle and Fibre Toxicology, 2016,13:4, DOI 10.1186/s12989-016-0115-y.
[7] Li et al. Suppression of PTPN6 exacerbates aluminum oxide nanoparticle-induced COPD-like lesions in mice through activation of STAT pathway[J]. Particle and Fibre Toxicology ,2017,14:53, DOI 10.1186/s12989-017-0234-0.
[8] Xiaobo Li, Jian Cui, Hongbao Yang,et al. Colonic Injuries Induced by Inhalational Exposure to Particulate-Matter Air Pollution[J]. Adv. Sci. 2019, 1900180. DOI: 10.1002/advs.201900180.
[9] Xiaobo Li, Hao Sun, Bin Li, et al. Probiotics Ameliorate Colon Epithelial Injury Induced by Ambient Ultrafine Particles Exposure[J]. Adv. Sci. 2019, 1900972. DOI: 10.1002/advs.201900972.
[10] Yingfeng Du, Ludan Hou, Chen Chu, et al. Characterization of serum metabolites as biomarkers of carbon black nanoparticles-induced subchronic toxicity in rats by hybrid triple quadrupole time-of-flight mass spectrometry with non-targeted metabolomics strategy{J}. Toxicology , 2019,426:152268.
[11] Bin Han, Chen Chu, Xuan Su, et al. N6-methyladenosinedependent primary microRNA-126 processing activated PI3K-AKT-mTOR pathway drove the development of pulmonary fibrosis induced by nanoscale carbon black particles in rats[J]. Nanotoxicology, 2019, DOI: 10.1080/17435390.2019.1661041.
[12] Chen Chu, Lixiao Zhou, Heran Xie, et al. Pulmonary toxicities from a 90-day chronic inhalation study with carbon black nanoparticles in rats related to the systemical immune effects[J]. International Journal of Nanomedicine, 2019,14: 2995–3013.