Ten-Channel Turntable Cigarette Smoke Generator - Automated Testing Solution from China Suppliers and Factory
Features
Smoke Channel
10
Smoke Capacity
15-60ml
Smoke Cycle
30-240s
Cigarette Bin Capacity
200 cigarettes
Combustion Abort Mode
By smoke number
Smoke Curve
Standard bell curve or customized
Application
Applicable to various toxicology research centers, animal smoking poisoning tests, respiratory laboratories of hospitals, technical laboratories of cigarette factories for smoke research, etc.
Working Environment
Temperature
0°C - 60°C
Humidity
5% - 95% (non-condensing)
Storage Environment
Temperature
-20°C - 70°C
Humidity
5% - 95% (non-condensing)
Two Smoking Modes
Puff Mode and Length Mode. Both modes support automatic cigarette loading, lighting, smoking, and ejection.
1) Puff Mode:
In this mode, the instrument records the number of puffs per cigarette. When the number of puffs per cigarette reaches the preset value, the cigarette will be ejected and a new cigarette will be inserted. The instrument will automatically stop and issue a reminder when the total number of puffs taken equals the preset total puffs.
2) Length Mode:
In this mode, cigarette ejection is performed by detecting whether the cigarette length reaches the user-set length. The next round of operation will start only after all 10 cigarettes in the current round reach the specified length. The instrument will automatically stop and issue a reminder when the total number of cigarettes reaches the preset value.
Puff Flow Rate: The flow rate for drawing a single puff. Adjustment range: 10 mL–60 mL.
Puffs per Cigarette: Sets the number of puffs per cigarette in Puff Mode. This button is grayed out and disabled in Length Mode.
Total Puffs: Sets the total number of puffs in Puff Mode. This button is grayed out and disabled in Length Mode.
Frequently Asked Questions
Q:
What are the key technical specifications of the smoking channels and capacity?
The instrument features 10 smoke channels, a smoke capacity range of 15-60ml, a smoke cycle of 30-240s, and a cigarette bin capacity of 200 cigarettes.
Q:
What are the primary applications of this smoking instrument?
It is widely applicable to toxicology research centers, animal smoking poisoning tests, hospital respiratory laboratories, and technical laboratories in cigarette factories for smoke research.
Q:
What environmental conditions are required for operation and storage?
For operation, the temperature must be 0°C-60°C with 5%-95% humidity (non-condensing). For storage, the temperature range is -20°C to 70°C with the same humidity requirements.
Q:
What is the difference between Puff Mode and Length Mode?
Puff Mode controls and ejects cigarettes based on a preset number of puffs per cigarette. Length Mode ejects cigarettes based on whether the physical length of the cigarette has reached the user-set limit.
Q:
Can I adjust the puff flow rate in these smoking modes?
Yes, the flow rate for drawing a single puff is adjustable, with an adjustment range of 10 mL to 60 mL.