Request a Quote
Leave Your Message

Two-fluid Liquid Aerosol Generator

By adopting multi-channel strong vortex atomization technology, model HRH-TAG1 Two-fluid Liquid Aerosol Generator can control the gas-liquid ratio precisely. Equipped with a particle-size sieving buffer chamber, it can obtain aerosol particle size distribution MMAD1-3m. GSD1.5-3 and meet inhalation requirements.

    Features

    1.Compared with the traditional aerosol generator, model HRH-TAG1 two-fluid liquid aerosol generator is suitable for viscous or heavy oils which are difficult to be generated.
    2.Can be connected to a peristaltic pump to add liquid to meet the long-term experimental needs.
    3.Streamlined design particle size sieving buffer chamber is removable and easy to clean.
    4.The generated aerosol MMAD1-3μm, GSD1.5-3.
    5.It can be easily connected with our nose-only exposure system for rodents.

    Application

    Fine atomization of various liquids.

    Requirements of inhalation toxicology and inhalation immunity.

    Applicable to generation of microbial aerosols and studies of animal inhalation infection models.

    It can be applied to inhalation toxicology research, aerobiology, aerosol research, biohazard testing, performance evaluation of filters, inhalation immunization, inhalation therapy, drug research, environmental evaluation, hazard assessment of biology and chemistry, and medical protection. Especially suitable for viscous or heavy oils which are difficult to be generated by traditional generators, also can be used for various water-soluble, oil-soluble and part of the fine particles stabilized suspension and other solutions samples.  

    Aerosol Generation

    After connecting the compressed air pipeline and aerosol pipeline, open the compressed air valve, the compressed air inside the two-flow nozzle forms high-speed rotary flow, resulting in a strong vortex circumstance, the liquid sample is pumped in by the peristaltic pump and then dispersed mixed with high-speed spray to form aerosols. Big particles impact to the buffer chamber wall or deposit in the forward process, and discharged through the waste liquid outlet, small particles will be output 
    from the aerosol outlet.

    Specification

    Specification of silicon tube in connection with liquid tube 2mmx4mm
    Outer diameter of PU tubes in connection with air compressor 4mmx6mm
    Aerosol outlet specification 16mmx20mm

    Standards

    ① OECD TG 403 Acute Inhalation Toxicity (2009).

    ② OECD TG 436 Acute Inhalation Toxicity. Acute Toxic Class Method (2009).

    ③ OECD TG 412 28d Sub-acute inhalation (2018).

    ④ OECD TG 413 90d Sub-chronic inhalation (2018).