Whole-Body Non-Invasive Plethysmography System for Rodents - China Suppliers & Factory Solutions
Features
- Simple to use no need surgery.
- Rodents can move freely in the plethysmograph without influence of anesthesia.
- Multiple rodents can be tested simultaneously.
- It can perform self-control and different rodents control.
- Equipped with drinking bottle, can perform long-time continuous test.
- Applicable to mice, rats, guinea pigs, etc.
| Parameters | Meaning |
|---|---|
| Ti | Inspiratory time (ms) |
| Te | Expiratory time (ms) |
| f | Respiratory rate (bpm) |
| TV | Tidal volume (mL) |
| MV | Minute ventilation (mL) |
| RT | Relaxation time (ms) |
| EV | Expiratory volume (mL) |
| PIF | Peak inspiratory flow (mL/min) |
| PEF | Peak expiratory flow (mL/min) |
| EEP | End-expiratory pause (ms) |
| Tbox | Body box temperature (°C) |
| Tbody | Animal body temperature (°C) |
| Patm | Atmospheric pressure (mmHg) |
| VCF | Correction factor |
| Penh | Enhanced pause / bronchoconstriction index |
| EF50 | 50% expiratory flow rate (mL/min) |
| EIP | End-inspiratory pause (ms) |
Application
Rodent Physiology Studies, Rodent Screening, Test Studies for Drug Safety Evaluation.
System Connection
Major Components
- Control cabinet
- Animal plethysmograph
- Pressure sensor
- Desiccant
- Data analysis system
Data Analysis Performance
- Real-time collection and analysis curve parameters, display the average value of respiratory parameters within 5s.
- Historical test data query, playback at the fastest 32x speed.
- Analysis data can be exported to Excel.
Specification
| Item | Channel 4 | Channel 8 |
|---|---|---|
| Communication Port | USB type-D | USB type-D |
| Sensor Range | ±1.0 H2O | ±1.0 H2O |
| Power Supply | 220VAC 50Hz | 220VAC 50Hz |
| Weight | 13.3kg | 15.5kg |
| Dimensions | 618x320x230mm | 618x320x230mm |
Working Conditions
Temp: 0℃~60℃
Humidity: 5%~95% (non-condensing)
Humidity: 5%~95% (non-condensing)
Storage Conditions
Temp: -20℃~70℃
Humidity: 5%~95% (non-condensing)
Humidity: 5%~95% (non-condensing)
Publications
[1] Wang Guanlin, Zhai Zizhao, Wang Wenhao, et al. Tailored Borneol-Modified Lipid Nanoparticles Nasal Spray for En- hanced Nose-to-Brain Delivery to Central Nervous System Diseases. ACS Nano, 2024, https://doi.org/10.1021/acsna-no.4c08279. (IF 15.8)
[2] Linjing Wu, Wenhao Wang, Mengqin Guo, et al. Inhalable iron redox cycling powered nanoreactor for amplified ferro- ptosis-apoptosis synergetic therapy of lung cancer. Nano Res. 2024, https://doi.org/10.1007/s12274-024-6455-2. (IF 9.5)
Frequently Asked Questions (FAQ)
Does the rodent plethysmograph system require surgery?
No, this system is simple to use and does not require surgery. Rodents can move freely in the plethysmograph without the influence of anesthesia.
Which animal species are applicable to this system?
The system is highly applicable to small laboratory animals including mice, rats, guinea pigs, and similar rodents.
Can the system perform long-time continuous testing?
Yes, the system is equipped with a drinking bottle, which allows it to perform long-time continuous tests effectively.
How many channels are available and what are the system specs?
The system comes in 4-channel and 8-channel configurations. Both feature USB type-D communication ports, a sensor range of ±1.0 H2O, and operate on 220VAC 50Hz power supply.
What parameters can the data analysis system measure?
The system measures critical parameters such as Inspiratory/Expiratory time (Ti/Te), Respiratory rate (f), Tidal volume (TV), Minute ventilation (MV), Relaxation time (RT), Peak flows (PIF/PEF), and Penh (Enhanced pause / bronchoconstriction index).
Can the data analysis results be exported?
Yes, the collected analysis data can be easily exported to Excel, and historical test data can be queried and played back at speeds up to 32x.