Request a Quote
Leave Your Message

Whole-body Non-invasive Plethysmography System for Rodents - Leading China Suppliers & Factory Direct Products

The Whole-body Non-invasive Plethysmography System is an essential tool for assessing respiratory physiological indexes in rodents such as mice, rats, and guinea pigs while they are awake and unrestrained. This advanced system allows researchers to evaluate key parameters related to animal bronchoconstriction and respiratory function effectively. As a leading manufacturer in China, our factory is dedicated to providing high-quality equipment that meets the needs of researchers and suppliers in the field. Trust us for innovative solutions that enhance your studies on animal physiology and respiratory health

    Features

    • Simple to use, no need for surgery.
    • Rodents can move freely in the plethysmograph without influence of anesthesia.
    • Multiple rodents can be tested simultaneously.
    • It can perform self-control and different rodents control.
    • Equipped with drinking bottle, can perform long-time continuous test.
    • Applicable to mice, rats, guinea pigs, etc.

    Parameters & Meanings

    Parameters Meaning
    Ti Inspiratory time (ms)
    Te Expiratory time (ms)
    f Respiratory rate (bpm)
    TV Tidal volume (mL)
    MV Minute ventilation (mL)
    RT Relaxation time (ms)
    EV Expiratory volume (mL)
    PIF Peak inspiratory flow (mL/min)
    PEF Peak expiratory flow (mL/min)
    EEP End-expiratory pause (ms)
    Tbox Body box temperature (°C)
    Tbody Animal body temperature (°C)
    Patm Atmospheric pressure (mmHg)
    VCF Correction factor
    Penh Enhanced pause / bronchoconstriction index
    EF50 50% expiratory flow rate (mL/min)
    EIP End-inspiratory pause (ms)

    Application

    Rodent Physiology Studies, Rodent Screening, Test Studies for Drug Safety Evaluation.

    System Connection

    System Connection

    Major Components

    • 1. Control cabinet
    • 2. Animal plethysmograph
    • 3. Pressure sensor
    • 4. Desiccant
    • 5. Data analysis system

    Data Analysis Performance

    • Real-time collection and analysis curve parameters, display the average value of respiratory parameters within 5s.
    • Historical test data query, playback at the fastest 32x speed.
    • Analysis data can be exported to Excel.
    Data Analysis Performance

    Specification

    Item Channel 4 Channel 8
    Communication Port USB type-D USB type-D
    Sensor Range ±1.0 H2O ±1.0 H2O
    Power Supply 220VAC 50Hz 220VAC 50Hz
    Weight 13.3kg 15.5kg
    Dimensions 618x320x230mm 618x320x230mm

    Working Conditions

    Temp: 0℃~60℃
    Humidity: 5%~95% (non-condensing)

    Storage Conditions

    Temp: -20℃~70℃
    Humidity: 5%~95% (non-condensing)

    Publications

    • [1] Wang Guanlin, Zhai Zizhao, Wang Wenhao, et al. Tailored Borneol-Modified Lipid Nanoparticles Nasal Spray for En- hanced Nose-to-Brain Delivery to Central Nervous System Diseases. ACS Nano, 2024, https://doi.org/10.1021/acsna-no.4c08279. (IF 15.8)
    • [2] Linjing Wu, Wenhao Wang, Mengqin Guo, et al. Inhalable iron redox cycling powered nanoreactor for amplified ferro- ptosis-apoptosis synergetic therapy of lung cancer. Nano Res. 2024, https://doi.org/10.1007/s12274-024-6455-2. (IF 9.5)

    Frequently Asked Questions (FAQ)

    Is surgery required to use this rodent plethysmograph system?

    No, the system is designed to be simple to use and does not require any surgical procedures. Rodents can move freely inside the plethysmograph without the influence of anesthesia.

    What animal species are compatible with the system?

    The system is highly versatile and applicable to various small rodents, including mice, rats, and guinea pigs.

    Can multiple channels/animals be tested at the same time?

    Yes, multiple rodents can be tested simultaneously. The system is available in 4-channel and 8-channel configurations to accommodate different experimental scales.

    What key parameters can be measured and analyzed?

    The system measures a comprehensive range of respiratory and physiological parameters, including Inspiratory/Expiratory time (Ti/Te), Respiratory rate (f), Tidal volume (TV), Minute ventilation (MV), and the Enhanced pause / bronchoconstriction index (Penh).

    How does the data analysis software perform?

    The software supports real-time collection and curve analysis (showing 5s averages), historical test data playback at up to 32x speed, and convenient data export to Excel formats.

    What are the environmental requirements for working and storage?

    The working environment should be maintained between 0℃~60℃. For storage, the temperature range is -20℃~70℃. Both conditions require a non-condensing relative humidity of 5%~95%.

    Make An AppointmentLEAVE YOUR MESSAGE