Whole-body Non-invasive Plethysmography System for Rodents - Leading China Suppliers & Factory Solutions
Features
- Simple to use no need surgery.
- Rodents can move freely in the plethysmograph without influence of anesthesia.
- Multiple rodents can be tested simultaneously.
- It can perform self-control and different rodents control.
- Equipped with drinking bottle, can perform long-time continuous test.
- Applicable to mice, rats, guinea pigs, etc.
| Parameters | Meaning |
| Ti | Inspiratory time (ms) |
| Te | Expiratory time (ms) |
| f | Respiratory rate (bpm) |
| TV | Tidal volume (mL) |
| MV | Minute ventilation (mL) |
| RT | Relaxation time (ms) |
| EV | Expiratory volume (mL) |
| PIF | Peak inspiratory flow (mL/min) |
| PEF | Peak expiratory flow (mL/min) |
| EEP | End-expiratory pause (ms) |
| Tbox | Body box temperature (°C) |
| Tbody | Animal body temperature (°C) |
| Patm | Atmospheric pressure (mmHg) |
| VCF | Correction factor |
| Penh | Enhanced pause / bronchoconstriction index |
| EF50 | 50% expiratory flow rate (mL/min) |
| EIP | End-inspiratory pause (ms) |
Application
Rodent Physiology Studies, Rodent Screening, Test Studies for Drug Safety Evaluation.
System Connection
Major Components
1 Control cabinet
2 Animal plethysmograph
3 Pressure sensor
4 Desiccant
5 Data analysis system
Data Analysis Performance
1 Real-time collection and analysis curve parameters, display the average value of respiratory parameters within 5s.
2 Historical test data query, playback at the fastest 32x speed.
3 Analysis data can be exported to Excel.
Specification
| Item | Channel 4 | Channel 8 |
| Communication Port | USB type-D | USB type-D |
| Sensor Range | ±1.0 H2O | ±1.0 H2O |
| Power Supply | 220VAC 50Hz | 220VAC 50Hz |
| Weight | 13.3kg | 15.5kg |
| Dimensions | 618x320x230mm | 618x320x230mm |
Working Conditions
Temp: 0℃~60℃
Humidity: 5%~95% (non-condensing)
Storage Conditions
Temp: -20℃~70℃
Humidity: 5%~95% (non-condensing)
Publications
[1] Wang Guanlin, Zhai Zizhao, Wang Wenhao, et al. Tailored Borneol-Modified Lipid Nanoparticles Nasal Spray for Enhanced Nose-to-Brain Delivery to Central Nervous System Diseases. ACS Nano, 2024, https://doi.org/10.1021/acsnano.4c08279. (IF 15.8)
[2] Linjing Wu, Wenhao Wang, Mengqin Guo, et al. Inhalable iron redox cycling powered nanoreactor for amplified ferroptosis-apoptosis synergetic therapy of lung cancer. Nano Res. 2024, https://doi.org/10.1007/s12274-024-6455-2. (IF 9.5)
Frequently Asked Questions
Is surgery required to use this plethysmograph system?
No, this system is simple to use and does not require any surgical procedures on the rodents.
Do rodents need to be anesthetized during the test?
No, rodents can move freely in the plethysmograph during the evaluation without the influence of anesthesia.
What parameters can the data analysis system collect?
The system collects and analyzes various respiratory parameters, including Inspiratory time (Ti), Expiratory time (Te), Respiratory rate (f), Tidal volume (TV), Minute ventilation (MV), Relaxation time (RT), and Enhanced pause / bronchoconstriction index (Penh), among others.
Can the analysis data be exported?
Yes, all collected analysis data can be easily exported to Excel for further research and documentation.
What are the main applications of this system?
The system is widely used for Rodent Physiology Studies, Rodent Screening, and Test Studies for Drug Safety Evaluation.
What channels are available for this system?
The system is available in 4-channel and 8-channel configurations to support testing multiple rodents simultaneously.