Whole-body Non-invasive Plethysmography System for Rodents - Quality China Suppliers & Factory Products
Features
- Simple to use, no need for surgery.
- Rodents can move freely in the plethysmograph without the influence of anesthesia.
- Multiple rodents can be tested simultaneously.
- It can perform self-control and different rodents control.
- Equipped with drinking bottle, can perform long-time continuous test.
- Applicable to mice, rats, guinea pigs, etc.
| Parameters | Meaning |
|---|---|
| Ti | Inspiratory time (ms) |
| Te | Expiratory time (ms) |
| f | Respiratory rate (bpm) |
| TV | Tidal volume (mL) |
| MV | Minute ventilation (mL) |
| RT | Relaxation time (ms) |
| EV | Expiratory volume (mL) |
| PIF | Peak inspiratory flow (mL/min) |
| PEF | Peak expiratory flow (mL/min) |
| EEP | End-expiratory pause (ms) |
| Tbox | Body box temperature (°C) |
| Tbody | Animal body temperature (°C) |
| Patm | Atmospheric pressure (mmHg) |
| VCF | Correction factor |
| Penh | Enhanced pause / bronchoconstriction index |
| EF50 | 50% expiratory flow rate (mL/min) |
| EIP | End-inspiratory pause (ms) |
Application
Rodent Physiology Studies, Rodent Screening, Test Studies for Drug Safety Evaluation.
System Connection
Major Components
- 1. Control cabinet
- 2. Animal plethysmograph
- 3. Pressure sensor
- 4. Desiccant
- 5. Data analysis system
Data Analysis Performance
- 1. Real-time collection and analysis curve parameters, display the average value of respiratory parameters within 5s.
- 2. Historical test data query, playback at the fastest 32x speed.
- 3. Analysis data can be exported to Excel.
Specification
| Item | Channel 4 | Channel 8 |
|---|---|---|
| Communication Port | USB type-D | USB type-D |
| Sensor Range | ±1.0 H2O | ±1.0 H2O |
| Power Supply | 220VAC 50Hz | 220VAC 50Hz |
| Weight | 13.3kg | 15.5kg |
| Dimensions | 618x320x230mm | 618x320x230mm |
Working Conditions
Temp: 0℃~60℃
Humidity: 5%~95% (non-condensing)
Storage Conditions
Temp: -20℃~70℃
Humidity: 5%~95% (non-condensing)
Publications
[1] Wang Guanlin, Zhai Zizhao, Wang Wenhao, et al. Tailored Borneol-Modified Lipid Nanoparticles Nasal Spray for En- hanced Nose-to-Brain Delivery to Central Nervous System Diseases. ACS Nano, 2024, https://doi.org/10.1021/acsna-no.4c08279. (IF 15.8)
[2] Linjing Wu, Wenhao Wang, Mengqin Guo, et al. Inhalable iron redox cycling powered nanoreactor for amplified ferro- ptosis-apoptosis synergetic therapy of lung cancer. Nano Res. 2024, https://doi.org/10.1007/s12274-024-6455-2. (IF 9.5)
Frequently Asked Questions
Is surgery required to use this rodent plethysmograph system?
No, the system is simple to use and does not require any surgical procedures on the rodents.
Are the rodents anesthetized during testing?
No, rodents can move freely in the plethysmograph chamber without the influence of anesthesia.
Can I test multiple animals simultaneously?
Yes, multiple rodents can be tested at the same time depending on the channel configuration (available in 4-channel and 8-channel models).
Is the system suitable for long-term continuous testing?
Yes, the system is equipped with a drinking bottle, making it fully capable of performing long-time continuous tests.
What types of animals are compatible with this system?
The system is applicable to small rodents including mice, rats, guinea pigs, and similar species.
Can the analyzed data be exported for further evaluation?
Yes, the data analysis system allows you to easily export the collected analysis parameters into Excel format.