Request a Quote
Leave Your Message

Whole-body Non-invasive Plethysmography System for Rodents - Quality China Suppliers & Factory Solutions

The Whole-body Non-invasive Plethysmography System is an advanced device designed for assessing respiratory physiological indexes in rodents, including mice, rats, and guinea pigs, while they are awake and unrestrained. This innovative system enables researchers to evaluate crucial parameters related to animal bronchoconstriction and respiratory function. As a leading supplier in China, we provide high-quality products directly from our factory, ensuring accuracy and reliability in respiratory testing for your research needs

    Features

    • Simple to use no need surgery.
    • Rodents can move freely in the plethysmograph without influence of anesthesia.
    • Multiple rodents can be tested simultaneously.
    • It can perform self-control and different rodents control.
    • Equipped with drinking bottle, can perform long-time continuous test.
    • Applicable to mice, rats, guinea pigs, etc.
    Parameters Meaning
    Ti Inspiratory time (ms)
    Te Expiratory time (ms)
    f Respiratory rate (bpm)
    TV Tidal volume (mL)
    MV Minute ventilation (mL)
    RT Relaxation time (ms)
    EV Expiratory volume (mL)
    PIF Peak inspiratory flow (mL/min)
    PEF Peak expiratory flow (mL/min)
    EEP End-expiratory pause (ms)
    Tbox Body box temperature (°C)
    Tbody Animal body temperature (°C)
    Patm Atmospheric pressure (mmHg)
    VCF Correction factor
    Penh Enhanced pause / bronchoconstriction index
    EF50 50% expiratory flow rate (mL/min)
    EIP End-inspiratory pause (ms)

    Application

    Rodent Physiology Studies, Rodent Screening, Test Studies for Drug Safety Evaluation.

    System Connection

    Major Components

    • Control cabinet
    • Animal plethysmograph
    • Pressure sensor
    • Desiccant
    • Data analysis system

    Data Analysis Performance

    • Real-time collection and analysis curve parameters, display the average value of respiratory parameters within 5s.
    • Historical test data query, playback at the fastest 32x speed.
    • Analysis data can be exported to Excel.

    Specification

    Item Channel 4 Channel 8
    Communication Port USB type-D USB type-D
    Sensor Range ±1.0 H2O ±1.0 H2O
    Power Supply 220VAC 50Hz 220VAC 50Hz
    Weight 13.3kg 15.5kg
    Dimensions 618x320x230mm 618x320x230mm
    Working Conditions

    Temp: 0℃~60℃
    Humidity: 5%~95% (non-condensing)

    Storage Conditions

    Temp: -20℃~70℃
    Humidity: 5%~95% (non-condensing)

    Publications

    [1] Wang Guanlin, Zhai Zizhao, Wang Wenhao, et al. Tailored Borneol-Modified Lipid Nanoparticles Nasal Spray for En- hanced Nose-to-Brain Delivery to Central Nervous System Diseases. ACS Nano, 2024, https://doi.org/10.1021/acsnano.4c08279. (IF 15.8)
    [2] Linjing Wu, Wenhao Wang, Mengqin Guo, et al. Inhalable iron redox cycling powered nanoreactor for amplified ferro- ptosis-apoptosis synergetic therapy of lung cancer. Nano Res. 2024, https://doi.org/10.1007/s12274-024-6455-2. (IF 9.5)

    Frequently Asked Questions (FAQ)

    What parameters can be measured during rodent physiology studies using this system?
    This system measures comprehensive respiratory parameters including Inspiratory time (Ti), Expiratory time (Te), Respiratory rate (f), Tidal volume (TV), Minute ventilation (MV), Relaxation time (RT), Expiratory volume (EV), Peak flows (PIF/PEF), and Penh (Enhanced pause / bronchoconstriction index).
    Does the animal need to be anesthetized during testing?
    No, surgery is not required. Rodents can move freely in the plethysmograph without the influence of anesthesia, ensuring more natural physiological data collection.
    How many channels are available for simultaneous testing?
    The system comes in configurations supporting either 4 channels or 8 channels, allowing multiple rodents to be tested simultaneously for self-control and comparative studies.
    Can the system perform long-time continuous testing?
    Yes, the system is equipped with a dedicated drinking bottle, making it fully applicable for long-time continuous monitoring and testing.
    What are the major components included in this system?
    The major components of the system include a Control cabinet, Animal plethysmograph chambers, Pressure sensors, Desiccant, and the Data analysis system software.
    What are the data export options for analysis?
    The system supports real-time parameter collection and analysis, allowing historical data playback up to 32x speed. Collected analysis data can be easily exported directly to Excel.

    Make An AppointmentLEAVE YOUR MESSAGE