Request a Quote
Leave Your Message

Whole-body Non-invasive Plethysmography System

The Whole-body Non-invasive Plethysmography System is used to test respiratory physiological indexes of rodents (e.g., mice, rats, guinea pigs, etc.) in their awake and unrestrained state, and evaluate parameters of animal bronchoconstriction, etc.

    Features

    Simple to use no need surgery.

    Rodents can move freely in the plethysmograph without influence of anesthesia.

    Multiple rodents can be tested simultaneously.

    It can perform self-control and different rodents control.

    Equipped with drinking bottle, can perform long-time continuous test.

    Applicable to mice, rats, guinea pigs, etc.

    The plethysmograph is injection-molded from transparent PC material, which is resistant to high temperature, high pressure, and common disinfectants, allowing unobstructed observation of animals from the outside.

    An optional animal lung function calibration platform is available for periodic calibration of the frequency and volume of the pulmonary function instrument, ensuring the accuracy of test results.

    Parameters

    Meaning

    Ti

    Inspiratory time (ms)

    Te

    Expiratory time (ms)

    f

    Respiratory rate (bpm)

    TV

    Tidal volume (mL)

    MV

    Minute ventilation (mL)

    RT

    Relaxation time (ms)

    EV

    Expiratory volume (mL)

    PIF

    Peak inspiratory flow (mL/min)

    PEF

    Peak expiratory flow (mL/min)

    EEP

    End-expiratory pause (ms)

    Tbox

    Body box temperature (°C)

    Tbody

    Animal body temperature (°C)

    Patm

    Atmospheric pressure (mmHg)

    VCF

    Correction factor

    Penh

    Enhanced pause / bronchoconstriction index

    EF50

    50% expiratory flow rate (mL/min)

    EIP

    End-inspiratory pause (ms)

    Application

    Rodent Physiology Studies, Rodent Screening, Test Studies for Drug Safety Evaluation.

    System Connection

    System Connection

    Major Components

    1. Control cabinet 
    2. Animal plethysmograph 
    3. Pressure sensor 
    4. Desiccant 
    5. Data analysis system 

    Data Analysis Performance

    1.Real-time collection and analysis curve parameters, display the average value of respiratory parameters within 5s.
    2.Historical test data query, playback at the fastest 32x speed.
    3.Analysis data can be exported to Excel.Data Analysis Performance

    Specification

    Item

    Channel 4

    Channel 8

    Communication Port

    USB type-D

    USB type-D

    Sensor Range

    ±1.0 H2O

    ±1.0 H2O

    Power Supply

    220VAC 50Hz

    220VAC 50Hz

    Weight

    13.3kg

    15.5kg

    Dimensions

    618x320x230mm

    618x320x230mm

    Working Conditions

    Temp: 0℃~60℃
    Humidity: 5%~95% (non-condensing)

    Storage Conditions

    Temp: -20℃~70℃
    Humidity: 5%~95% (non-condensing)

    Publications

    [1] Wang Guanlin, Zhai Zizhao, Wang Wenhao, et al. Tailored Borneol-Modified Lipid Nanoparticles Nasal Spray for En- hanced Nose-to-Brain Delivery to Central Nervous System Diseases. ACS Nano, 2024, https://doi.org/10.1021/acsna- no.4c08279.(IF 15.8)
    [2] Linjing Wu, Wenhao Wang, Mengqin Guo, et al. Inhalable iron redox cycling powered nanoreactor for amplified ferro- ptosis-apoptosis synergetic therapy of lung cancer. Nano Res. 2024, https://doi.org/10.1007/s12274-024-6455-2. (IF 9.5)

    Typical Users

    A*STAR Research Entities
    Jinan University
    Wuhan Hongren Biopharmaceutical Inc.
    Ji'nan Jingyuan Experimental Instrument Co. Ltd.
    Shenzhen First Union Technology Co.,Ltd.
    Encore (Shanxi) Biological Cell Co., Ltd.
    Yunnan woyi Biological Technology Co. Ltd.
    Suzhou Municipal Hospital
    The Second Affiliated Hospital of Nanchang University
    The First Affiliated Hospital of Nanchang University

    Make An AppointmentLEAVE YOUR MESSAGE